Isonics Silicon Products and Services Division - Reclaim Process Flow

Sorting and Incoming Inspection
The Isonics wafer reclaim process ensures that wafers will remain contaminant free throughout the entire wafer reclaim cycle. We start with 100% visual inspection of the wafers. This visual inspection of all wafers provides critical information on wafer films and possible wafer damage; this inspection is also our first line of protection against possible wafer or equipment contamination. We guarantee that Isonics reclaim wafers can be placed directly in use in your fab with high confidence in their quality and safety.

Reclaim Wafer Preparation
After a thorough inspection of incoming silicon wafers, the appropriate chemistry is determined to remove existing oxide, films or patterns. This may include a piranha solution for organic matter, or an alkaline or acid etch as required to remove films. This preparation brings bare silicon to the wafer surface as originally manufactured. As an additional fail-safe, Isonics applies a pre-treatment to reclaim wafers that may contain metal films (such as Al) to ensure that wafers enter the wafer reclaim line metal free.

Wafer Surface Restoration
Occasionally the silicon wafer surface requires lapping or grinding to remove films from wafers slated for reclaim. Isonics uses state-of-the-art equipment for wafer grinding and lapping assuring optimal surface condition, better stress relief, and low material removal. Isonics Wafer Thinning is a natural extension of our expertise in wafer surface conditioning. We have been recognized by the EMC-3D industry consortium as their vendor of choice for wafer thinning with capabilities down to 75um for 100mm and 200mm wafers and down to 200um for 300mm wafers. For more information see http://www.emc3d.org/

Polishing
Based on our customer's wafer reclaim specifications, Isonics will provide single side or double side wafer polishing resulting in a high-quality finish with optimal flatness across the wafer. Our double side polishing achieves the lowest total thickness variation (TTV) and our single side polishing ensures a high quality front surface while preserving the condition of the backside of the wafer. We tailor our wafer polishing process for each customer to provide the minimum removal possible to achieve the desired specification. This results in maximum wafer reuse cycles for our customers.

Ultra-Pure and Ultra-Clean
Following wafer polishing, reclaim wafers are moved to the Isonics Class 1 Clean room where they are cleaned in multiple stages. Isonics uses fresh chemistry (cleaning agents) or single pass cleaning, for each run to prevent cross-contamination. Our cleaning process ensures low particle counts and we guarantee surface metal levels of less than 5e10 atoms per cm2. Typically Isonics wafer cleaning performs at even lower surface metals of less than 1e10 (below detection limit) for most customers.

Inspection
Wafer particles, or light point defects (LPDs) are measured by an industry standard laser particle scanner including our newest KLA Tencor SP1. Isonics actually has two KLA SP1s on site in Vancouver, a model SP1-DLS and a SP1-TBI, the same models used by leading semiconductor manufacturers in their fabs. The Isonics wafer reclaim process is capable of achieving very low particulate levels, LPDs below 50@0.080 um or 30@0.12 um for 300mm reclaim wafers is possible. As part of our Wafer Reclaim Quality procedure, we conduct storage simulation tests to ensure the wafers remain clean even after extended storage periods (simulating >12 month worst case scenarios).

Data Integrity and Reporting
Isonics provides a comprehensive report on our wafer reclaim products; the C of A (certificate of analysis) reports the results by lot.
Isonics can also provide custom reporting as needed:
- Reconciliation report of wafer yields
- Wafer Metrology
- Full histogram data